* adis16507: enhance driver to handle and recover from all failure modes
- Clean up driver
- Add optional hardware reset
- Fix scale and range for 125 deg/s variant
- Handle communication errors when read returns zeroes
- Improved perf counters
* change prints to PX4_DEBUG, define BURST_READ_CMD, do both soft and hard reset, use ScheduleNow instead of 1ms delay, change read/write stall period to SPI_STALL value
- sensor_baro.msg use SI (pressure in Pascals)
- update all barometer drivers to publish directly and remove PX4Barometer helper
- introduce baro cal (offset) mainly as a mechanism to adjust
relative priority
- commander: add simple baro cal that sets baro offsets to align with
GPS altitude (if available)
- create new sensors_status.msg to generalize sensor reporting
- minor scheduling improvements
- if expected number of samples larger than expected adjust timestamp sample and save sample for next iteration
- when scheduling via data ready interrupt (with no FIFO watermark) count continuously without clearing
- increase SPI stall time slightly
- tolerate mag self test failure (could be due to local magnetic field)
- register configuration compatible with older ADIS16448AMLZ
- don't publish duplicate accel/gyro
- only allocate CRC perf counter if using CRC
- new IMU driver structure with state machine (no sleeps in bus thread)
- verify all configured registers and trigger reset on failure
- detect if DIO1 or DIO2 are actually connected for data ready interrupt usage
- don't use CRC-16 on burst transfers except for verified lots