Jacob Dahl 7f59e5dc16 fix(bmp280): correct timestamp_sample to integration midpoint
The BMP280 pressure measurement is integrated over _measure_interval
(~43ms at 16x pressure / 2x temperature oversampling). The read time
corresponds to the end of the integration window, introducing a
systematic timing bias. Correct timestamp_sample to the midpoint by
subtracting measurement_time / 2.
2026-03-31 16:37:12 -08:00
..
2025-03-10 18:59:52 -04:00