- Enable arbitrary euler angle for Mag rotation
- new CUSTOM rotation enum out of the normal enum range
- mag_rot: automatically change to custom if euler rot is set
- sensor_calibration: Magnetometer save custom rotation parameters
- mag_cal: cross mention rotation parameters
- This allows the user to see the RPY options when searching for the rotation parameter
---------
Co-authored-by: Junwoo Hwang <junwoo@auterion.com>
Co-authored-by: bresch <[brescianimathieu@gmail.com](mailto:brescianimathieu@gmail.com)>
Co-authored-by: Daniel Agar <daniel@agar.ca>
Fix a memory overflow in case SENS_BOARD_ROT is set to Rotation::ROTATION_MAX (41) which is not a valid value
Signed-off-by: Jukka Laitinen <jukkax@ssrc.tii.ae>
- since last_us is set to 0 every time the bias is not observable, the
total time was also reset -> needed 30 consecutive seconds in mag 3D
to be declared "stable"
- after landing, the mag_aligned_in_flight flag is reset. Using this for
bias validity makes it invalid before we have a chance to save it to
the calibration.
This allows to consistently define:
Motor stopped - disarmed PWM
Motor idling - minimum PWM
Motor at full thrust - maximum PWM
Any allocation can then distinctly decide if
a motor should be running or not depending
on the context and also explicitly command that.
That state only delayed the first arming by 50 miliseconds.
Was presumably a workaround for some issue very very early on.
See cc452834c0dabd2689f5f102ce1cbbe714f056dd
Before:
When the mixed throttle for the motor was exactly zero the ramp went
from the disarmed PWM value to the minimum PWM value.
When the throttle was even just slightly different from zero the ramp
made a jump up to the commanded throttle scaled between
disarmed PWM and maximum PWM, then ramped between
disarmed PWM and minimum PWM and at the end jumped up again to
the commanded throttle scaled between minimum PWM and maximum PWM.
After:
The ramp goes from disarmed PWM value to the the
commanded throttle scaled between minimum PWM and maximum PWM.
If the commanded throttle changes during the ramp then the scale and
hence also end value of the ramp changes.
- Instead we disable interrups on Nuttx where needed
- No lock is held during param export. Params can be changed
concurrently and we rely on the fact that another export will be
triggered in that case.
* RateControl: rename setGains to setPidGains to be more precise
Signed-off-by: Silvan Fuhrer <silvan@auterion.com>
* FW Rate controller: only allow to disable Yaw in Acro, not roll and pitch
Signed-off-by: Silvan Fuhrer <silvan@auterion.com>
---------
Signed-off-by: Silvan Fuhrer <silvan@auterion.com>