Commit Graph

51 Commits

Author SHA1 Message Date
Daniel Agar d59d16a6cd drivers/accelerometer: adjust int16_t clipping threshold slightly
- consider data clipped/saturated if it's INT16_MIN/INT16_MAX or within 1
 - this accommodates rotated data (|INT16_MIN| = INT16_MAX + 1) and sensors that may re-use the lowest bit for other purposes (sync indicator, etc)
2021-12-15 12:45:58 -05:00
Jukka Laitinen d02a10b20f Remove src/lib/drivers/accelerometer and gyroscope linking to drivers__device
These are pure uORB publishers, they don't link to drivers__device.

Signed-off-by: Jukka Laitinen <jukkax@ssrc.tii.ae>
2021-11-10 09:26:36 -05:00
Daniel Agar 089f96f800 lib/drivers/{accelerometer,gyroscope} skip obselete Vector3f construction
- FIFO clip count only check if value is INT16_MIN/MAX rather than abs() call
2021-10-08 17:33:27 -04:00
Daniel Agar 883624d915 lib/geo: move from ecl 2021-07-15 10:38:24 -04:00
David Sidrane 42e51b0215 PX4Accelerometer:Fix types 2021-06-16 17:07:47 +02:00
Daniel Agar 8478d1ea37 sensors/vehicle_angular_velocity: properly handle filter reset on FIFO data scale changes
For the sake of efficiency (at 8 kHz) all filtering is performed on the raw data before the calibration and rotation is applied to only the final output. As a result we have to be a bit more careful when switching between sensors or in cases where the gyro scale factor changes (eg icm42688p 20 bit data rescaled to fit in int16 output).
2021-04-25 14:20:32 -04:00
Daniel Agar 047fb13922 IMU_GYRO_RATEMAX: enforce reasonable constraint and update metadata 2021-04-13 20:26:57 -04:00
Daniel Agar e57aaaaa5e rotate accel/gyro FIFO before publish and fix angular velocity filter resets
- rotates accel & gyro FIFO data before publication both to simplify downstream usage (including log review) and fix other issues
     - to best handle int16_t data rotations are now either performed with swaps if possible, otherwise promoted to float, rotated using the full rotation matrix, then rounded back to int16_t
 - fix sensors/vehicle_angular_velocity filter reset both with proper rotation and new calibration uncorrect helper
      - in FIFO case filtering is done before calibration is applied, but we need to handle a possible reset from a completely different sensor (vehicle body angular velocity -> sensor frame uncorrected data)
2021-03-22 12:01:12 -04:00
Dima Ponomarev e660b50021 uavcan: add IMU sensor support 2021-03-17 18:04:12 -04:00
Daniel Agar 5f3e883f2c sensors/vehicle_imu: vehicle_imu_status include accel/gyro full raw FIFO sample rate 2021-02-24 08:13:53 -05:00
Daniel Agar a57b9f9381 delete drv_baro.h, drv_mag.h, drv_range_finder.h, drv_device.h and purge UAVCAN CDev usage 2021-01-12 22:04:52 -05:00
FengShun eac9a6b68b Replace PublicationQueued with Publication to automatically configure ORB_QUEUE_LENGTH 2020-10-26 13:01:13 +01:00
Daniel Agar 378cb155d6 simulator: support accel/gyro instances and stuck failure
- expand simulator to 3 accels and gyros
 - PX4Accelerometer/PX4Gyroscope switch to old param usage due to copy constructor issues with ModuleParams
2020-10-07 13:20:13 -04:00
Daniel Agar 44c877c603 sensors: size sensor error_count consistently (uint32_t) 2020-08-21 10:12:13 -04:00
Daniel Agar 27f23ac290 move initial sensor priority to parameters and purge ORB_PRIORITY
- CAL_ACCx_EN -> CAL_ACCx_PRIO
 - CAL_GYROx_EN -> CAL_GYROx_PRIO
 - CAL_MAGx_EN -> CAL_MAGx_PRIO
2020-08-21 10:12:13 -04:00
Daniel Agar 56c86e77bd replace FIFOSample -> sensor_accel_fifo/sensor_gyro_fifo 2020-06-18 20:49:15 -04:00
Daniel Agar f55ed0992c accel and gyro calibration refactor and cleanup
- remove all remaining IOCTLs for accel and gyro and handle all calibration entirely in sensors module with parameters
 - sensor_accel and sensor_gyro are now always raw sensor data
 - calibration procedures no longer need to first clear existing values before starting
 - temperature calibration (TC) remove all scale (SCL) parameters
    - gyro and baro scale are completely unused
    - regular accel calibration scale can be used (CAL_ACC*_xSCALE) instead of TC scale
2020-06-17 22:50:09 -04:00
Daniel Agar e819f99064 new Bosch BMI055 IMU driver using FIFOs and DRDY
- accel & gyro FIFOs enabled
 - FIFO watermark on data ready interrupt
 - sensor side filtering completely disabled
 - gyro now respects `IMU_GYRO_RATEMAX` (up to 2 kHz)
 - saves a few % cpu (at default rate)
2020-06-15 10:19:14 -04:00
Daniel Agar 13e34b32e6 new Bosch BMI088 IMU driver using FIFOs and DRDY 2020-06-11 12:25:13 -04:00
Daniel Agar 31fe7af454 selectively increase optimization -Os -> -O2
- targetted at modules/libraries that benefit without drastically
increasing flash usage
 - ignored on boards with CONSTRAINED_FLASH set
2020-06-04 20:59:52 -04:00
Daniel Agar e34bdb4be9 move IMU integration out of drivers to sensors hub to handle accel/gyro sync
- IMU integration move from drivers (PX4Accelerometer/PX4Gyroscope) to sensors/vehicle_imu 
 - sensors: voted_sensors_update now consumes vehicle_imu
 - delete sensor_accel_integrated, sensor_gyro_integrated
 - merge sensor_accel_status/sensor_gyro_status into vehicle_imu_status
 - sensors status output minor improvements (ordering, whitespace, show selected sensor device id and instance)
2020-05-30 11:07:54 -04:00
Daniel Agar ca998c1822 IMU: parameterize IMU integration time (IMU_INTEG_RATE)
- default integration rate now 200 Hz (5000 us interval)
 - set update rate for all drivers and simulators using PX4Accelerometer/PX4Gyroscope
2020-05-05 20:34:09 -04:00
Daniel Agar 466b5db36f uORB::Publication improvements and cleanup (#14784)
- create common uORB::PublicationBase
 - uORB::PublicationQueued types are now type aliases
 - ORB_PRIO use enum type everywhere to avoid accidental misuse
 - PX4Accelerometer/PX4Gyroscope/etc driver libs explicitly advertise on construction, unadvertise on destruction. This is a workaround for any potential issues that might appear when accel/gyro cdev and uORB indexing doesn't align.
2020-05-04 11:09:30 -04:00
Daniel Agar 3832214145 PX4Accelerometer/PX4Gyroscope: fix calibration offset for integrated FIFO case
This is a quick follow up fix to to a bug introduced by #14752. In the case of FIFO data (new IMU drivers) the calibration offset wasn't being applied correctly to the result of integrating the FIFO samples.

This slipped through basic sanity testing (simple bench testing, the test rack, and SITL CI) due to the calibration offsets being zeroed.
2020-04-26 13:24:51 -04:00
Daniel Agar 37d5d1b4d2 PX4Accelerometer/PX4Gyroscope: integrated data avoid loss of numerical precision 2020-04-26 14:28:50 +02:00
Daniel Agar 31f3a21849 update ecl/EKF with improved covariance prediction stability and change default IMU integration period 4000 us -> 2500 us
- bring in PX4/ecl#795 "EKF: Improve covariance prediction stability"
    - the ecl/EKF filter update period has changed from 8 ms to 10 ms
 - change default integration period 4000 us -> 2500 us (aligns with new EKF filter update period)
2020-04-23 13:55:34 -04:00
Daniel Agar cf37be8c44 ekf2 handle accelerometer clipping
- track clipping per IMU axis and pass through to ecl/EKF
 - update ecl/EKF to include delta velocity clipping changes (PX4/ecl#663)
2020-04-07 20:11:08 -04:00
Daniel Agar 2b82b471c1 sensor_accel_fifo increase to 32 samples 2020-03-31 13:26:50 -04:00
Daniel Agar afc59f843c invensense icm20602 improvements
- refactor Run() into simple state machine
 - perform reset and configuration in sensor bus thread
 - when using data ready interrupt skip checking FIFO count
2020-02-22 12:15:52 -05:00
Daniel Agar 22499effb9 invensense icm20602 improvements
- checked register mechanism and simple watchdog
    - driver checks for errors gradually and can reconfigure itself
 - respect IMU_GYRO_RATEMAX at the driver level
 - fixed sensor INT16_MIN and INT16_MAX handling (y & z axis are flipped before publishing)
 - increased sensor_gyro_fifo max size (enables running the driver much slower, but still transferring all raw data)
 - PX4Accelerometer/PX4Gyroscope remove unnecessary memsets
2020-02-18 19:21:20 -05:00
Daniel Agar d7c3e1066a uavcannode updates and px4_fmu-v4_cannode example
- drivers/uavcannode add baro, mag, gps publications
 - delete old px4_cannode-v1 board
 - add stripped down simple rcS for CAN nodes
2020-02-16 12:11:54 -05:00
Daniel Agar 2410b31662 sensors: move accel filtering to sensors/vehicle_acceleration
I've added a queue depth of 4 for sensor_accel and sensor_gyro. This is initially added because it's not always possible for the `vehicle_acceleration` to keep up with every publication of the primary accelerator as it runs in the same thread as ekf2, various controllers, etc. 

Later this mechanism will be used in a few areas
 - rate limit `vehicle_angular_velocity` and `vehicle_acceleration` without missing any raw data
 - move IMU integration to `vehicle_imu` and out of the actual driver threads, eliminating the need for sensor_accel_integrated and sensor_gyro_integrated
 - integrate raw gyro synchronized with optical flow measurements
2020-01-29 16:13:38 -05:00
Daniel Agar 009ba638f5 PX4Accelerometer/PX4Gyroscope update FIFO case to trapezoidal integration 2020-01-22 18:35:41 -05:00
Daniel Agar dc05ceaad2 create temperature_compensation module
- this is a new module for temperature compensation that consolidates the functionality previously handled in the sensors module (calculating runtime thermal corrections) and the events module (online thermal calibration)
 - by collecting this functionality into a single module we can optionally disable it on systems where it's not used and save some flash (if disabled at build time) or memory (disabled at run time)
2020-01-20 21:42:42 -05:00
Daniel Agar bb465ca5b7 sensor accel/gyro message cleanup
- split out integrated data into new standalone messages (sensor_accel_integrated and sensor_gyro_integrated)
 - publish sensor_gyro at full rate and remove sensor_gyro_control
 - limit sensor status publications to 10 Hz
 - remove unused accel/gyro raw ADC fields
 - add device IDs to sensor_bias and sensor_correction
    - vehicle_angular_velocity/vehicle_acceleration: check device ids before using bias and corrections
2020-01-18 01:15:00 -05:00
Daniel Agar 1d932f6ec9 IMU drivers using FIFOs increase max length to 16 and sync similar implementations
- this provides some extra space when the FIFO transfers don't align perfectly
 - I've also made an effort to keep the different drivers (icm20602, icm20608g, ism330ldc) in sync so we can factor out the common portions later once we've confident in the pattern.
2020-01-17 22:06:09 -05:00
Daniel Agar b60a519cbc drivers accel & gyroscope: use float for integrator accumulation
- fixes Coverity CID 352841 and CID 352840
2020-01-05 21:30:40 -05:00
Daniel Agar 89e1f478ac PX4Accelerometer and PX4Gyroscope add vibration metrics and always publish status 2019-12-27 20:54:50 -05:00
Daniel Agar 1a395fb6d9 ST ISM330DLC IMU driver 2019-12-03 16:16:49 -05:00
Beat Küng 3198610f85 src/platforms: move all headers to platforms/common/include/px4_platform_common
and remove the px4_ prefix, except for px4_config.h.

command to update includes:
for k in app.h atomic.h cli.h console_buffer.h defines.h getopt.h i2c.h init.h log.h micro_hal.h module.h module_params.h param.h param_macros.h posix.h sem.h sem.hpp shmem.h shutdown.h tasks.h time.h workqueue.h; do for i in $(grep -rl 'include <px4_'$k src platforms boards); do sed -i 's/#include <px4_'$k'/#include <px4_platform_common\/'$k/ $i; done; done
for in $(grep -rl 'include <px4_config.h' src platforms boards); do sed -i 's/#include <px4_config.h/#include <px4_platform_common\/px4_config.h'/ $i; done

Transitional headers for submodules are added (px4_{defines,log,time}.h)
2019-10-30 11:48:47 +01:00
Daniel Agar 35398e05ca perf counter cleanup (mostly intervals)
Some of these perf counters were useful during initial development, but realistically aren't needed anymore, some are redundant when we can now see the average interval from `work_queue status` and some of them simply aren't worth the cost at higher rates.
2019-10-21 18:54:17 -04:00
Daniel Agar e8a11086eb create uORB::PublicationMulti for multi publications 2019-08-08 21:01:56 -04:00
Daniel Agar 6a6bc4be58 drivers helper classes remove empty publication (forced advertise)
- this is no longer necessary with all publications outside of ISRs
2019-08-03 14:08:45 -04:00
Daniel Agar 9450496eb4 Analog Devices ADIS16497 move to PX4Accelerometer/PX4Gyroscope and cleanup 2019-07-01 22:47:31 -04:00
Daniel Agar 79d4c09d59 uORB::Publication simplify and cleanup
- base class is now template
 - drop linked list
 - virtualization no longer required
2019-06-12 08:48:19 -04:00
Daniel Agar cd45d8fc68 fxas21002c split out main and header 2019-05-31 18:20:32 -04:00
Daniel Agar 43e3fc707d simulator move to PX4Accelerometer, PX4Gyroscope, PX4Magnetometer, PX4Barometer helpers (#12081) 2019-05-30 21:07:26 -04:00
Beat Küng 03332aaa20 PX4Accelerometer,PX4Gyroscope: set_sample_rate requires a filter update 2019-05-29 09:15:52 +02:00
bresch b14446f0e5 Parameter update - Rename variables in lib
using paramter_update.py script
2019-04-03 15:38:50 +02:00
Daniel Agar 5a841761ce PX4Accelerometer apply sensor rotation before scaling
- prevents loss of numerical precision
 - fixes #11695
2019-03-24 18:34:31 -04:00