Commit Graph
29 Commits
Author SHA1 Message Date
Alex Klimaj 4d1c65d722 boards: new ARK FPV FC (#23830)
* add new payload power switch (RC_MAP_PAY_SW)
2024-10-30 11:35:35 -04:00
Matthias Grob 42fa41e601 rc_update: fix on-off-switch with negative threshold values 2023-07-11 15:58:48 +02:00
Matthias Grob e127ada07b rc_update: extend ModuleParams::updateParams() for local parameter updates 2023-07-11 15:58:48 +02:00
Matthias Grob 87c697a0d6 rc_update: switch back to protected scope and use fixture for testing 2023-07-11 15:58:48 +02:00
Matthias Grob 7b6f45079b ManualControl: use input validity flag to check for RC calibration 2023-05-23 17:24:17 +02:00
Silvan Fuhrer b16f16598b VTOL: remove virtual actuator_controls and instead use virtual torque/thrust topics
MC/FW rate controller and auto tuner: remove actuator_controls

AirshipAttControl: remove actuator_controls

MulticopterLandDetector: remove actuator_controls

mavlink streams vfr_hud and high_latency2: remove actuator_controls

RoverPositionController: remove actuator_controls

UUVAttitudeController: remove actuator_controls

battery: use length of thrust_setpoint for throttle compensation

VehicleMagnetometer: use length of thrust_setpoint for throttle compensation

Signed-off-by: Silvan Fuhrer
2023-03-16 11:55:45 +01:00
Daniel Agar 13f9eabd70 delete unused actuator_controls_3 2022-09-09 09:14:09 -04:00
Beat Küng 7e75b497ae helicopter: add switch to engage main motor
For helicopters it's useful (e.g. during bringup) to be able to disable
the main rotor while the tail is still controlled to safely land.
2022-09-07 08:00:26 +02:00
Matthias Grob 4bd2d4cf35 rc_update: add unit tests for mode slot
To verify RC mode switch and mode button functionality works as expected.
2022-05-16 14:37:29 +02:00
Daniel Agar 77a37c26bf rc_update: further tighten timing requirements for valid data
- any real RC data input will be much faster than 3 Hz, so this is an
easy way to minimize bogus decoded data from propagating
2022-04-07 14:42:05 -04:00
Matthias Grob fabf865411 Use backwards compatible manual_control_setpoint instead of manual_control_input 2021-11-09 16:05:25 +01:00
Julian Oes 14eb656a59 rc_update: use snake_case for namespace name 2021-11-09 16:05:25 +01:00
Julian Oes 6e8ccf6a45 rc_update: rename update method
This reflects better what it actually does.
2021-11-09 16:05:25 +01:00
Daniel Agar 2d816e0b3e [WIP] manual_control selector hacks 2021-11-09 16:05:25 +01:00
Daniel AgarandBeat Küng 089c962d92 px4io: moving mixing to FMU side
Using mixers on the IO side had a remote benefit of being able to
override all control surfaces with a radio remote on a fixed wing.
This ended up not being used that much and since the original design
10 years ago (2011) we have been able to convince ourselves that the
overall system stability is at a level where this marginal benefit,
which is not present on multicopters, is not worth the hazzle.

Co-authored-by: Beat Küng <beat-kueng@gmx.net>
Co-authored-by: Daniel Agar <daniel@agar.ca>
2021-09-25 19:15:05 -04:00
Claudio Micheli c50daae4a3 rc_update: introduce support for toggle buttons via RC channels
Signed-off-by: Claudio Micheli <claudio@auterion.com>
2021-09-14 09:52:32 +02:00
Daniel Agar bb12fce66c delete RATTITUDE flight mode 2021-03-09 10:47:00 -05:00
Kalyan Sriram b257f9d1fd actuator: add support for MAV_CMD_DO_SET_ACTUATOR
Adds support for using the MAVLink command MAV_CMD_DO_SET_ACTUATOR to
update the actuator values on control group 3 aux{1, 2, 3}. A simple
deconfliction with rc_update is implemented: when a MAVLink command is
sent, RC is disabled for that channel until a major stick movement is
detected.
2021-03-02 12:41:02 +01:00
Daniel Agar 967d35a6b6 rate limit most parameter_update subscriptions
- parameter updates can be quite expensive because they trigger nearly all modules to reload all of their parameters immediately
 - limit modules from updating faster than once per second
2021-01-10 21:09:15 -05:00
Daniel AgarandMatthias Grob ef6209ba03 new manual_control_switches msg (split out of manual_control_setpoint) (#16270)
- split out switches from manual_control_setpoint into new message manual_control_switches
 - manual_control_switches published at minimal rate (~ 1 Hz) or immediately on change
 - simple switch debounce in rc_update (2 consecutive identical decodes required)
 - manual_control_switches logged at full rate rather than sampled at (5-10% of messages logged)
 - manual_control_setpoint publish at minimal rate unless changing
 - commander handle landing gear switch for manual modes
 - processing of mode_slot and mode_switch is now split so we only do one or the other (not both)
     - a future step will be to finally drop mode_switch and accompanying switches entirely

Co-authored-by: Matthias Grob <maetugr@gmail.com>
2020-12-11 12:11:35 -05:00
Daniel Agar 85f3ab1960 rc_update: only decode if RC input is stable (channel count and source) 2020-12-01 09:40:24 -05:00
Daniel Agar 27f23ac290 move initial sensor priority to parameters and purge ORB_PRIORITY
- CAL_ACCx_EN -> CAL_ACCx_PRIO
 - CAL_GYROx_EN -> CAL_GYROx_PRIO
 - CAL_MAGx_EN -> CAL_MAGx_PRIO
2020-08-21 10:12:13 -04:00
Daniel Agar 63a23957b1 rc/dsm: decode improvements
- always check system field for validity
 - reject any data outside of "servo position" valid range from Spektrum specification
 - properly support XPlus channels (12+)
 - debug message if channel count changes
2020-08-02 12:52:16 -04:00
Matthias Grob e9eae1bd76 Refactor: Name manual_control_setpoint the same way everywhere 2020-06-22 12:06:27 -04:00
Matthias Grob 27586db93e rc_update: remove obsolete RC filtering 2020-05-20 19:30:19 +02:00
Daniel Agar 21a8d7db7f WorkItem modules: Run() shouldn't be public 2020-01-22 12:03:03 -05:00
Daniel Agar 57fc98812d rc_update: cleanup parameter usage 2019-12-23 23:47:34 +01:00
Daniel Agar 22a005c9f4 delete module's redundant print_status()
- we can already get the running status from ModuleBase and the other misc information is already available through perf or uORB
2019-11-30 18:22:19 -05:00
Daniel Agar bc182e94e6 sensors split rc_update into new standalone module 2019-11-24 13:25:11 -05:00