- Do not pull in PWM parameters when DISABLE_PARAMS_MODULE_SCOPING is TRUE since VOXL2 has no PWM nor any of the required timer_config files that go along with that
- Replace non-standard M_PI constants with PX4 defined M_PI_F constants
- Include missing header file for function hrt_absolute_time declaration
- Add new PX4_SOC_ARCH_ID for the VOXL2 board
Instead of always starting with instance 0 (potentially an internal
mag), first take the current sensor as reference to compare the other
ones against it.
The issue is that otherwise we can end up in a
situation where a switch occurs because the currently used sensor isn't
much better than a sensor with a lower index: because the selected one
isn't much better, we cannot "fail-over" to it and get stuck on another
sensor, triggering a fail-over.
- sensor_baro.msg use SI (pressure in Pascals)
- update all barometer drivers to publish directly and remove PX4Barometer helper
- introduce baro cal (offset) mainly as a mechanism to adjust
relative priority
- commander: add simple baro cal that sets baro offsets to align with
GPS altitude (if available)
- create new sensors_status.msg to generalize sensor reporting