Commit Graph

12 Commits

Author SHA1 Message Date
Marco Hauswirth 39abd87949 set best sensor to -1 after last sensor fails (#23425) 2024-07-24 11:24:07 +02:00
Eric Katzfey c3e70b03aa Add more to Voxl2 build and fix associated build errors (#20821)
- Do not pull in PWM parameters when DISABLE_PARAMS_MODULE_SCOPING is TRUE since VOXL2 has no PWM nor any of the required timer_config files that go along with that
 - Replace non-standard M_PI constants with PX4 defined M_PI_F constants
 - Include missing header file for function hrt_absolute_time declaration
 - Add new PX4_SOC_ARCH_ID for the VOXL2 board
2022-12-22 15:44:19 -05:00
bresch 8e3517fae0 DataValidator: fix unexpected failover
Instead of always starting with instance 0 (potentially an internal
mag), first take the current sensor as reference to compare the other
ones against it.
The issue is that otherwise we can end up in a
situation where a switch occurs because the currently used sensor isn't
much better than a sensor with a lower index: because the selected one
isn't much better, we cannot "fail-over" to it and get stuck on another
sensor, triggering a fail-over.
2022-12-06 08:16:23 +01:00
Daniel Agar 0c31f63896 sensors: add baro calibration and cleanup
- sensor_baro.msg use SI (pressure in Pascals)
 - update all barometer drivers to publish directly and remove PX4Barometer helper
 - introduce baro cal (offset) mainly as a mechanism to adjust
relative priority
 - commander: add simple baro cal that sets baro offsets to align with
GPS altitude (if available)
 - create new sensors_status.msg to generalize sensor reporting
2022-03-26 16:08:41 -04:00
Daniel Agar dd6b7fa98f sensors: switch status PX4_INFO -> PX4_INFO_RAW 2022-01-18 15:00:18 -05:00
Daniel Agar b1d2a0cc4e sensors: simplify timestamp data validator handling 2022-01-18 14:57:18 -05:00
Daniel Agar a5a457d744 sensors: relax default data_validator timeout 20->40ms 2021-09-01 15:16:00 -04:00
Daniel Agar 713a1d08a3 sensors: add accel/gyro current priority to sensors_status_imu
- later the sensor priorities (user configurable) can be factored into the estimator selection criteria
2021-07-30 21:20:01 -04:00
Julian Oes be3cdc0439 sensors: correct comment logic
By removing the no the comment matches the implementation (which I think
makes sense).
2021-02-04 10:14:44 +01:00
Daniel Agar 44c877c603 sensors: size sensor error_count consistently (uint32_t) 2020-08-21 10:12:13 -04:00
Daniel Agar 971b1e4b4d sensors: move mag aggregation to new VehicleMagnetometer WorkItem
- purge all reminaing magnetometer IOCTL usage
 - mag calibration add off diagonal (soft iron) scale factors
2020-08-21 10:12:13 -04:00
Daniel Agar 87250ca47f move ecl L1, TECS, and data validator to PX4/Firmware 2020-06-18 19:26:30 -04:00