* Unfortunately, due to the SWIG dependency, we need sudo to install on
Travis (conflicts when adding with debian-sid source prevent using addons)
which means we cannot use the container-based infrastructure anymore.
* Building the Python bindings requires g++5 (at least with -Werr set).
* When building the Python bindings on Travis, the numpy includes are not found
by cmake, so they have to be added separately by running a Python process with
`numpy.get_include()`
* The build script now (somewhat clumsily) depends on the RUN_PYTEST environment
variable. If it is set to anything other than "", it will make the tests and
run tests and benchmarks
* Add requirements.txt file with required Python packages
* Read requirements.txt from CMakeLists.txt to check dependencies and alert the
user if necessary.
* Add SWIG interface definition (and external numpy interface) to ecl classes
* Add section in CMakeLists.txt to build Python bindings and execute
Python-based tests
* Write (property-based) tests that show the basic functionality of the Python
bindings and the EKF (using pytest and hypothesis libraries)
* Write minimal benchmark for the EKF update (using benchmark plugin for pytest)
* Add plotting utilities to analyze tests
* Add lint script to keep the Python scripts clean
* This is a sane choice (and should arguably always be done for classes with
virtual methods to avoid undefined behavior)
* It is required for wrapping the EstimatorInterface with SWIG (without virtual
destructor, deriving from the EstimatorInterface leads to
-Werror=delete-non-virtual-dtor).
Use the board supplied Power control macros, in the
the board_peripheral_reset.
This abstacts the polarity from the code. Therefore changes
in signal sense can be made, just in the board config.
RC00 had an active high VDD_5V_PERIPH_EN
PC01 has an active low VDD_5V_PERIPH_EN
RC00 Test hardware did not use an LTC4417
While RC00 HW is still in circulation you can build with
PX4_FMUV5_RC00 defined and BOARD_HAS_LTC4417 undefined.
The default is PX4_FMUV5_RC01 and BOARD_HAS_LTC4417 defined.
control_data needs to be able to be set to nullptr in case if the input
is already active. Otherwise the output will think there's always new
requests and reset it's state.