Paul Riseborough fa07536314 EKF: Prevent rounding errors causing bad conditioned covariance matrix
The previous practice of relying on the off-diagonals being zero caused problems with conditioning of the magnetometer fusion on one flight. By storing the variances when the learning inhibit becomes active and ensuring that the rows and columns in the covariance matrix for the inhibited states are always zero, the observed numerical conditioning error has been eliminated for replay of the problem flight log .