Commit Graph
4 Commits
Author SHA1 Message Date
Daniel Agar c5b1fe86ca delete deprecated BAT_* parameters 2021-07-08 22:19:12 -04:00
bazooka joe 190b96a46c SMbus battery driver - a lot of updates and optimizations
- added support for BQ40Z80 based battery
- added performance counter for interface errors
- added SMART_BATTERY_INFO mavlink message
- general code cleanups and optimization
- fixed: void flooding the log in case of interface error
- fixed: using _batt_startup_capacity instead of _batt_capacity for discharged_mah
- update: read manufacture_date
- update: get _cell_count from parameter and not const 4
- update: avoid re-reading data that has already been read and stored on class already
- currently the battery type defined by BAT_SMBUS_MODEL parameter and not by auto detection
2020-08-18 21:41:19 -04:00
Hyon LimandHyon Lim 3bcd8c63f8 SMBus battery (a.k.a. smart battery) enhancement. (#14496)
* Enhancement: State of health, and max_error value is added. Both shows battery health of SMBUS smart battery.
 * Enhancement: BAT_C_MULT parameter is introduced. This is for high-current capable SMBUS-based battery.
As SMBUS only provides 16-bit for current, it could only be +-32768mA which is about +-32A.
But with proper treatment, it could be extended with little accuracy loss.
This factor can be set for individual battery system with available information.
    * Relative SOC introduced. Proper SMBUS battery should provide percentage of remaining battery
directly. Therefore it does not have to be computed like before.
    * State of Health introduced. Proper SMBUS battery should provide SOH value.
    * Max error: this shows estimation error of BMS.
 * Enhancement: With smart battery, precise estimation of time remaining is provided
with impedance track. It is unit of minute, so 60 seconds multiplied.
Update rate of this is not fast, but very useful.

Co-authored-by: Hyon Lim <lim@uvify.com>
2020-03-31 17:28:22 -04:00
dakejahl 311c0941c9 Teal One airframe improvements for full support (#10860)
* added a parameter for enabled the smart battery
* start tel1 and tel2 at 921600 and max rate
* turned up the max tx rate on mavlink streams for telem1 and telem2
* turned off mavlink stream for tel1 in 4250_teal. This is connected to TX1 FTDI UART and has issues.
* moved check to 4250 board ID to start mpu9250s for Teal airframe into fmuv4 rc.board.
2018-12-05 09:49:58 -05:00