- extract motion checks performed on ground
- move all non-timing check to controlOpticalFlowFusion. This simplifies and standardirzes the setOpticalFlowData function. Furthermore, in some cases (SITL, PX4Flow), the dt is forced to 0 when the quality is 0 (which is usual on ground) so the ekf needs to ignore those values on ground to initialize properly the flow fusion.
- add filter convergence test
- move check for dt time max in setOpticalFlowData
- in the simulator, do not update dt as this is the sensor integration
period.
This is how it is also done in ekf2_main. Otherwise, this leads to
multiple integration of the same IMU data due to asynchronous sensor
updates triggering a prediction step between IMU updates.
Fix unit tests that broke because of this fix
* Add primitive logging for Ekf
* Add python script to extract sensor data from ULog
* Add primitive sensor replay
* Add iris_gps data for sensor replay
* Add CI for functional change indication
* Update sensor replay flow data type
* update iris_gps_change indication
* test: Update EKF replay test documentation
Co-authored-by: Paul Riseborough <priseborough@users.noreply.github.com>
* Fix comment
* Ekf wrapper for testing
Add utility function for accessing information in the ekf object
* Add step function for Gps sensor
* Add RangeFinder and Flow to simulated sensors
* Add first fusion logic tests
* Add units to function name
* Use EXPECT_TRUE
* Adding missing qualifiers
* Improve EXPECT_ calls
* Improve naming