@@ -15,7 +15,7 @@ Data can be gathered using the following sequence:
1) Power up the board and set the TC_A_ENABLE, TC_B_ENABLE and TC_G_ENABLE parameters to 1 1) Power up the board and set the TC_A_ENABLE, TC_B_ENABLE and TC_G_ENABLE parameters to 1
2) Set all CAL_GYR and CAL_ACC parameters to defaults 2) Set all CAL_GYR and CAL_ACC parameters to defaults
3) Set the SDLOG_MODE parameter to 2, and SDLOG_PROFILE parameter to 4 to enable logging of sensor data for calibration and power off 3) Set the parameter SDLOG_MODE to 2, and SDLOG_PROFILE "Thermal calibration" bit (2) to enable logging of sensor data for calibration and power off
4) Cold soak the board for 30 minutes 4) Cold soak the board for 30 minutes
5) Move to a warm dry, still air, constant pressure environment. 5) Move to a warm dry, still air, constant pressure environment.
6) Apply power for 45 minutes, keeping the board still. 6) Apply power for 45 minutes, keeping the board still.