Files
PX4-Autopilot/src/drivers/ms5611/ms5611.cpp
T
Andrew Tridgell fdbc09e2a5 avoid counters going above limit in INCREMENT()
when using INCREMENT() the counter would temporarily read equal to
limit, which could cause an issue if the task is preempted.

(this macro should be in a common header, though which header?)
2013-08-28 11:16:30 +02:00

1061 lines
25 KiB
C++

/****************************************************************************
*
* Copyright (C) 2012-2013 PX4 Development Team. All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions
* are met:
*
* 1. Redistributions of source code must retain the above copyright
* notice, this list of conditions and the following disclaimer.
* 2. Redistributions in binary form must reproduce the above copyright
* notice, this list of conditions and the following disclaimer in
* the documentation and/or other materials provided with the
* distribution.
* 3. Neither the name PX4 nor the names of its contributors may be
* used to endorse or promote products derived from this software
* without specific prior written permission.
*
* THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
* "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
* LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
* FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
* COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
* INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
* BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS
* OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED
* AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
* ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
* POSSIBILITY OF SUCH DAMAGE.
*
****************************************************************************/
/**
* @file ms5611.cpp
* Driver for the MS5611 barometric pressure sensor connected via I2C or SPI.
*/
#include <nuttx/config.h>
#include <sys/types.h>
#include <stdint.h>
#include <stdbool.h>
#include <stdlib.h>
#include <semaphore.h>
#include <string.h>
#include <fcntl.h>
#include <poll.h>
#include <errno.h>
#include <stdio.h>
#include <math.h>
#include <unistd.h>
#include <nuttx/arch.h>
#include <nuttx/wqueue.h>
#include <nuttx/clock.h>
#include <arch/board/board.h>
#include <drivers/device/device.h>
#include <drivers/drv_baro.h>
#include <drivers/drv_hrt.h>
#include <systemlib/perf_counter.h>
#include <systemlib/err.h>
#include "ms5611.h"
/* oddly, ERROR is not defined for c++ */
#ifdef ERROR
# undef ERROR
#endif
static const int ERROR = -1;
#ifndef CONFIG_SCHED_WORKQUEUE
# error This requires CONFIG_SCHED_WORKQUEUE.
#endif
/* helper macro for handling report buffer indices */
#define INCREMENT(_x, _lim) do { __typeof__(_x) _tmp = _x+1; if (_tmp >= _lim) _tmp = 0; _x = _tmp; } while(0)
/* helper macro for arithmetic - returns the square of the argument */
#define POW2(_x) ((_x) * (_x))
/*
* MS5611 internal constants and data structures.
*/
/* internal conversion time: 9.17 ms, so should not be read at rates higher than 100 Hz */
#define MS5611_CONVERSION_INTERVAL 10000 /* microseconds */
#define MS5611_MEASUREMENT_RATIO 3 /* pressure measurements per temperature measurement */
class MS5611 : public device::CDev
{
public:
MS5611(device::Device *interface, ms5611::prom_u &prom_buf);
~MS5611();
virtual int init();
virtual ssize_t read(struct file *filp, char *buffer, size_t buflen);
virtual int ioctl(struct file *filp, int cmd, unsigned long arg);
/**
* Diagnostics - print some basic information about the driver.
*/
void print_info();
protected:
Device *_interface;
ms5611::prom_s _prom;
struct work_s _work;
unsigned _measure_ticks;
unsigned _num_reports;
volatile unsigned _next_report;
volatile unsigned _oldest_report;
struct baro_report *_reports;
bool _collect_phase;
unsigned _measure_phase;
/* intermediate temperature values per MS5611 datasheet */
int32_t _TEMP;
int64_t _OFF;
int64_t _SENS;
/* altitude conversion calibration */
unsigned _msl_pressure; /* in kPa */
orb_advert_t _baro_topic;
perf_counter_t _sample_perf;
perf_counter_t _measure_perf;
perf_counter_t _comms_errors;
perf_counter_t _buffer_overflows;
/**
* Initialize the automatic measurement state machine and start it.
*
* @note This function is called at open and error time. It might make sense
* to make it more aggressive about resetting the bus in case of errors.
*/
void start_cycle();
/**
* Stop the automatic measurement state machine.
*/
void stop_cycle();
/**
* Perform a poll cycle; collect from the previous measurement
* and start a new one.
*
* This is the heart of the measurement state machine. This function
* alternately starts a measurement, or collects the data from the
* previous measurement.
*
* When the interval between measurements is greater than the minimum
* measurement interval, a gap is inserted between collection
* and measurement to provide the most recent measurement possible
* at the next interval.
*/
void cycle();
/**
* Static trampoline from the workq context; because we don't have a
* generic workq wrapper yet.
*
* @param arg Instance pointer for the driver that is polling.
*/
static void cycle_trampoline(void *arg);
/**
* Issue a measurement command for the current state.
*
* @return OK if the measurement command was successful.
*/
virtual int measure();
/**
* Collect the result of the most recent measurement.
*/
virtual int collect();
};
/*
* Driver 'main' command.
*/
extern "C" __EXPORT int ms5611_main(int argc, char *argv[]);
MS5611::MS5611(device::Device *interface, ms5611::prom_u &prom_buf) :
CDev("MS5611", BARO_DEVICE_PATH),
_interface(interface),
_prom(prom_buf.s),
_measure_ticks(0),
_num_reports(0),
_next_report(0),
_oldest_report(0),
_reports(nullptr),
_collect_phase(false),
_measure_phase(0),
_TEMP(0),
_OFF(0),
_SENS(0),
_msl_pressure(101325),
_baro_topic(-1),
_sample_perf(perf_alloc(PC_ELAPSED, "ms5611_read")),
_measure_perf(perf_alloc(PC_ELAPSED, "ms5611_measure")),
_comms_errors(perf_alloc(PC_COUNT, "ms5611_comms_errors")),
_buffer_overflows(perf_alloc(PC_COUNT, "ms5611_buffer_overflows"))
{
// work_cancel in stop_cycle called from the dtor will explode if we don't do this...
memset(&_work, 0, sizeof(_work));
}
MS5611::~MS5611()
{
/* make sure we are truly inactive */
stop_cycle();
/* free any existing reports */
if (_reports != nullptr)
delete[] _reports;
// free perf counters
perf_free(_sample_perf);
perf_free(_measure_perf);
perf_free(_comms_errors);
perf_free(_buffer_overflows);
delete _interface;
}
int
MS5611::init()
{
int ret;
ret = CDev::init();
if (ret != OK) {
debug("CDev init failed");
goto out;
}
/* allocate basic report buffers */
_num_reports = 2;
_reports = new struct baro_report[_num_reports];
if (_reports == nullptr) {
debug("can't get memory for reports");
ret = -ENOMEM;
goto out;
}
_oldest_report = _next_report = 0;
/* get a publish handle on the baro topic */
memset(&_reports[0], 0, sizeof(_reports[0]));
_baro_topic = orb_advertise(ORB_ID(sensor_baro), &_reports[0]);
if (_baro_topic < 0) {
debug("failed to create sensor_baro object");
ret = -ENOSPC;
goto out;
}
ret = OK;
out:
return ret;
}
ssize_t
MS5611::read(struct file *filp, char *buffer, size_t buflen)
{
unsigned count = buflen / sizeof(struct baro_report);
int ret = 0;
/* buffer must be large enough */
if (count < 1)
return -ENOSPC;
/* if automatic measurement is enabled */
if (_measure_ticks > 0) {
/*
* While there is space in the caller's buffer, and reports, copy them.
* Note that we may be pre-empted by the workq thread while we are doing this;
* we are careful to avoid racing with them.
*/
while (count--) {
if (_oldest_report != _next_report) {
memcpy(buffer, _reports + _oldest_report, sizeof(*_reports));
ret += sizeof(_reports[0]);
INCREMENT(_oldest_report, _num_reports);
}
}
/* if there was no data, warn the caller */
return ret ? ret : -EAGAIN;
}
/* manual measurement - run one conversion */
/* XXX really it'd be nice to lock against other readers here */
do {
_measure_phase = 0;
_oldest_report = _next_report = 0;
/* do temperature first */
if (OK != measure()) {
ret = -EIO;
break;
}
usleep(MS5611_CONVERSION_INTERVAL);
if (OK != collect()) {
ret = -EIO;
break;
}
/* now do a pressure measurement */
if (OK != measure()) {
ret = -EIO;
break;
}
usleep(MS5611_CONVERSION_INTERVAL);
if (OK != collect()) {
ret = -EIO;
break;
}
/* state machine will have generated a report, copy it out */
memcpy(buffer, _reports, sizeof(*_reports));
ret = sizeof(*_reports);
} while (0);
return ret;
}
int
MS5611::ioctl(struct file *filp, int cmd, unsigned long arg)
{
switch (cmd) {
case SENSORIOCSPOLLRATE: {
switch (arg) {
/* switching to manual polling */
case SENSOR_POLLRATE_MANUAL:
stop_cycle();
_measure_ticks = 0;
return OK;
/* external signalling not supported */
case SENSOR_POLLRATE_EXTERNAL:
/* zero would be bad */
case 0:
return -EINVAL;
/* set default/max polling rate */
case SENSOR_POLLRATE_MAX:
case SENSOR_POLLRATE_DEFAULT: {
/* do we need to start internal polling? */
bool want_start = (_measure_ticks == 0);
/* set interval for next measurement to minimum legal value */
_measure_ticks = USEC2TICK(MS5611_CONVERSION_INTERVAL);
/* if we need to start the poll state machine, do it */
if (want_start)
start_cycle();
return OK;
}
/* adjust to a legal polling interval in Hz */
default: {
/* do we need to start internal polling? */
bool want_start = (_measure_ticks == 0);
/* convert hz to tick interval via microseconds */
unsigned ticks = USEC2TICK(1000000 / arg);
/* check against maximum rate */
if (ticks < USEC2TICK(MS5611_CONVERSION_INTERVAL))
return -EINVAL;
/* update interval for next measurement */
_measure_ticks = ticks;
/* if we need to start the poll state machine, do it */
if (want_start)
start_cycle();
return OK;
}
}
}
case SENSORIOCGPOLLRATE:
if (_measure_ticks == 0)
return SENSOR_POLLRATE_MANUAL;
return (1000 / _measure_ticks);
case SENSORIOCSQUEUEDEPTH: {
/* add one to account for the sentinel in the ring */
arg++;
/* lower bound is mandatory, upper bound is a sanity check */
if ((arg < 2) || (arg > 100))
return -EINVAL;
/* allocate new buffer */
struct baro_report *buf = new struct baro_report[arg];
if (nullptr == buf)
return -ENOMEM;
/* reset the measurement state machine with the new buffer, free the old */
stop_cycle();
delete[] _reports;
_num_reports = arg;
_reports = buf;
start_cycle();
return OK;
}
case SENSORIOCGQUEUEDEPTH:
return _num_reports - 1;
case SENSORIOCRESET:
/* XXX implement this */
return -EINVAL;
case BAROIOCSMSLPRESSURE:
/* range-check for sanity */
if ((arg < 80000) || (arg > 120000))
return -EINVAL;
_msl_pressure = arg;
return OK;
case BAROIOCGMSLPRESSURE:
return _msl_pressure;
default:
break;
}
/* give it to the bus-specific superclass */
// return bus_ioctl(filp, cmd, arg);
return CDev::ioctl(filp, cmd, arg);
}
void
MS5611::start_cycle()
{
/* reset the report ring and state machine */
_collect_phase = false;
_measure_phase = 0;
_oldest_report = _next_report = 0;
/* schedule a cycle to start things */
work_queue(HPWORK, &_work, (worker_t)&MS5611::cycle_trampoline, this, 1);
}
void
MS5611::stop_cycle()
{
work_cancel(HPWORK, &_work);
}
void
MS5611::cycle_trampoline(void *arg)
{
MS5611 *dev = reinterpret_cast<MS5611 *>(arg);
dev->cycle();
}
void
MS5611::cycle()
{
int ret;
/* collection phase? */
if (_collect_phase) {
/* perform collection */
ret = collect();
if (ret != OK) {
if (ret == -6) {
/*
* The ms5611 seems to regularly fail to respond to
* its address; this happens often enough that we'd rather not
* spam the console with a message for this.
*/
} else {
//log("collection error %d", ret);
}
/* reset the collection state machine and try again */
start_cycle();
return;
}
/* next phase is measurement */
_collect_phase = false;
/*
* Is there a collect->measure gap?
* Don't inject one after temperature measurements, so we can keep
* doing pressure measurements at something close to the desired rate.
*/
if ((_measure_phase != 0) &&
(_measure_ticks > USEC2TICK(MS5611_CONVERSION_INTERVAL))) {
/* schedule a fresh cycle call when we are ready to measure again */
work_queue(HPWORK,
&_work,
(worker_t)&MS5611::cycle_trampoline,
this,
_measure_ticks - USEC2TICK(MS5611_CONVERSION_INTERVAL));
return;
}
}
/* measurement phase */
ret = measure();
if (ret != OK) {
//log("measure error %d", ret);
/* reset the collection state machine and try again */
start_cycle();
return;
}
/* next phase is collection */
_collect_phase = true;
/* schedule a fresh cycle call when the measurement is done */
work_queue(HPWORK,
&_work,
(worker_t)&MS5611::cycle_trampoline,
this,
USEC2TICK(MS5611_CONVERSION_INTERVAL));
}
int
MS5611::measure()
{
int ret;
perf_begin(_measure_perf);
/*
* In phase zero, request temperature; in other phases, request pressure.
*/
unsigned addr = (_measure_phase == 0) ? ADDR_CMD_CONVERT_D2 : ADDR_CMD_CONVERT_D1;
/*
* Send the command to begin measuring.
*/
ret = _interface->ioctl(IOCTL_MEASURE, addr);
if (OK != ret)
perf_count(_comms_errors);
perf_end(_measure_perf);
return ret;
}
int
MS5611::collect()
{
int ret;
uint32_t raw;
perf_begin(_sample_perf);
/* this should be fairly close to the end of the conversion, so the best approximation of the time */
_reports[_next_report].timestamp = hrt_absolute_time();
/* read the most recent measurement - read offset/size are hardcoded in the interface */
ret = _interface->read(0, (void *)&raw, 0);
if (ret < 0) {
perf_count(_comms_errors);
perf_end(_sample_perf);
return ret;
}
/* handle a measurement */
if (_measure_phase == 0) {
/* temperature offset (in ADC units) */
int32_t dT = (int32_t)raw - ((int32_t)_prom.c5_reference_temp << 8);
/* absolute temperature in centidegrees - note intermediate value is outside 32-bit range */
_TEMP = 2000 + (int32_t)(((int64_t)dT * _prom.c6_temp_coeff_temp) >> 23);
/* base sensor scale/offset values */
_SENS = ((int64_t)_prom.c1_pressure_sens << 15) + (((int64_t)_prom.c3_temp_coeff_pres_sens * dT) >> 8);
_OFF = ((int64_t)_prom.c2_pressure_offset << 16) + (((int64_t)_prom.c4_temp_coeff_pres_offset * dT) >> 7);
/* temperature compensation */
if (_TEMP < 2000) {
int32_t T2 = POW2(dT) >> 31;
int64_t f = POW2((int64_t)_TEMP - 2000);
int64_t OFF2 = 5 * f >> 1;
int64_t SENS2 = 5 * f >> 2;
if (_TEMP < -1500) {
int64_t f2 = POW2(_TEMP + 1500);
OFF2 += 7 * f2;
SENS2 += 11 * f2 >> 1;
}
_TEMP -= T2;
_OFF -= OFF2;
_SENS -= SENS2;
}
} else {
/* pressure calculation, result in Pa */
int32_t P = (((raw * _SENS) >> 21) - _OFF) >> 15;
/* generate a new report */
_reports[_next_report].temperature = _TEMP / 100.0f;
_reports[_next_report].pressure = P / 100.0f; /* convert to millibar */
/* altitude calculations based on http://www.kansasflyer.org/index.asp?nav=Avi&sec=Alti&tab=Theory&pg=1 */
/*
* PERFORMANCE HINT:
*
* The single precision calculation is 50 microseconds faster than the double
* precision variant. It is however not obvious if double precision is required.
* Pending more inspection and tests, we'll leave the double precision variant active.
*
* Measurements:
* double precision: ms5611_read: 992 events, 258641us elapsed, min 202us max 305us
* single precision: ms5611_read: 963 events, 208066us elapsed, min 202us max 241us
*/
/* tropospheric properties (0-11km) for standard atmosphere */
const double T1 = 15.0 + 273.15; /* temperature at base height in Kelvin */
const double a = -6.5 / 1000; /* temperature gradient in degrees per metre */
const double g = 9.80665; /* gravity constant in m/s/s */
const double R = 287.05; /* ideal gas constant in J/kg/K */
/* current pressure at MSL in kPa */
double p1 = _msl_pressure / 1000.0;
/* measured pressure in kPa */
double p = P / 1000.0;
/*
* Solve:
*
* / -(aR / g) \
* | (p / p1) . T1 | - T1
* \ /
* h = ------------------------------- + h1
* a
*/
_reports[_next_report].altitude = (((pow((p / p1), (-(a * R) / g))) * T1) - T1) / a;
/* publish it */
orb_publish(ORB_ID(sensor_baro), _baro_topic, &_reports[_next_report]);
/* post a report to the ring - note, not locked */
INCREMENT(_next_report, _num_reports);
/* if we are running up against the oldest report, toss it */
if (_next_report == _oldest_report) {
perf_count(_buffer_overflows);
INCREMENT(_oldest_report, _num_reports);
}
/* notify anyone waiting for data */
poll_notify(POLLIN);
}
/* update the measurement state machine */
INCREMENT(_measure_phase, MS5611_MEASUREMENT_RATIO + 1);
perf_end(_sample_perf);
return OK;
}
void
MS5611::print_info()
{
perf_print_counter(_sample_perf);
perf_print_counter(_comms_errors);
perf_print_counter(_buffer_overflows);
printf("poll interval: %u ticks\n", _measure_ticks);
printf("report queue: %u (%u/%u @ %p)\n",
_num_reports, _oldest_report, _next_report, _reports);
printf("TEMP: %d\n", _TEMP);
printf("SENS: %lld\n", _SENS);
printf("OFF: %lld\n", _OFF);
printf("MSL pressure: %10.4f\n", (double)(_msl_pressure / 100.f));
printf("factory_setup %u\n", _prom.factory_setup);
printf("c1_pressure_sens %u\n", _prom.c1_pressure_sens);
printf("c2_pressure_offset %u\n", _prom.c2_pressure_offset);
printf("c3_temp_coeff_pres_sens %u\n", _prom.c3_temp_coeff_pres_sens);
printf("c4_temp_coeff_pres_offset %u\n", _prom.c4_temp_coeff_pres_offset);
printf("c5_reference_temp %u\n", _prom.c5_reference_temp);
printf("c6_temp_coeff_temp %u\n", _prom.c6_temp_coeff_temp);
printf("serial_and_crc %u\n", _prom.serial_and_crc);
}
/**
* Local functions in support of the shell command.
*/
namespace ms5611
{
MS5611 *g_dev;
void start();
void test();
void reset();
void info();
void calibrate(unsigned altitude);
/**
* MS5611 crc4 cribbed from the datasheet
*/
bool
crc4(uint16_t *n_prom)
{
int16_t cnt;
uint16_t n_rem;
uint16_t crc_read;
uint8_t n_bit;
n_rem = 0x00;
/* save the read crc */
crc_read = n_prom[7];
/* remove CRC byte */
n_prom[7] = (0xFF00 & (n_prom[7]));
for (cnt = 0; cnt < 16; cnt++) {
/* uneven bytes */
if (cnt & 1) {
n_rem ^= (uint8_t)((n_prom[cnt >> 1]) & 0x00FF);
} else {
n_rem ^= (uint8_t)(n_prom[cnt >> 1] >> 8);
}
for (n_bit = 8; n_bit > 0; n_bit--) {
if (n_rem & 0x8000) {
n_rem = (n_rem << 1) ^ 0x3000;
} else {
n_rem = (n_rem << 1);
}
}
}
/* final 4 bit remainder is CRC value */
n_rem = (0x000F & (n_rem >> 12));
n_prom[7] = crc_read;
/* return true if CRCs match */
return (0x000F & crc_read) == (n_rem ^ 0x00);
}
/**
* Start the driver.
*/
void
start()
{
int fd;
prom_u prom_buf;
if (g_dev != nullptr)
/* if already started, the still command succeeded */
errx(0, "already started");
device::Device *interface = nullptr;
/* create the driver, try SPI first, fall back to I2C if unsuccessful */
if (MS5611_spi_interface != nullptr)
interface = MS5611_spi_interface(prom_buf);
if (interface == nullptr && (MS5611_i2c_interface != nullptr))
interface = MS5611_i2c_interface(prom_buf);
if (interface == nullptr)
errx(1, "failed to allocate an interface");
if (interface->init() != OK) {
delete interface;
errx(1, "interface init failed");
}
g_dev = new MS5611(interface, prom_buf);
if (g_dev == nullptr) {
delete interface;
errx(1, "failed to allocate driver");
}
if (g_dev->init() != OK)
goto fail;
/* set the poll rate to default, starts automatic data collection */
fd = open(BARO_DEVICE_PATH, O_RDONLY);
if (fd < 0) {
warnx("can't open baro device");
goto fail;
}
if (ioctl(fd, SENSORIOCSPOLLRATE, SENSOR_POLLRATE_DEFAULT) < 0) {
warnx("failed setting default poll rate");
goto fail;
}
exit(0);
fail:
if (g_dev != nullptr) {
delete g_dev;
g_dev = nullptr;
}
errx(1, "driver start failed");
}
/**
* Perform some basic functional tests on the driver;
* make sure we can collect data from the sensor in polled
* and automatic modes.
*/
void
test()
{
struct baro_report report;
ssize_t sz;
int ret;
int fd = open(BARO_DEVICE_PATH, O_RDONLY);
if (fd < 0)
err(1, "%s open failed (try 'ms5611 start' if the driver is not running)", BARO_DEVICE_PATH);
/* do a simple demand read */
sz = read(fd, &report, sizeof(report));
if (sz != sizeof(report))
err(1, "immediate read failed");
warnx("single read");
warnx("pressure: %10.4f", (double)report.pressure);
warnx("altitude: %11.4f", (double)report.altitude);
warnx("temperature: %8.4f", (double)report.temperature);
warnx("time: %lld", report.timestamp);
/* set the queue depth to 10 */
if (OK != ioctl(fd, SENSORIOCSQUEUEDEPTH, 10))
errx(1, "failed to set queue depth");
/* start the sensor polling at 2Hz */
if (OK != ioctl(fd, SENSORIOCSPOLLRATE, 2))
errx(1, "failed to set 2Hz poll rate");
/* read the sensor 5x and report each value */
for (unsigned i = 0; i < 5; i++) {
struct pollfd fds;
/* wait for data to be ready */
fds.fd = fd;
fds.events = POLLIN;
ret = poll(&fds, 1, 2000);
if (ret != 1)
errx(1, "timed out waiting for sensor data");
/* now go get it */
sz = read(fd, &report, sizeof(report));
if (sz != sizeof(report))
err(1, "periodic read failed");
warnx("periodic read %u", i);
warnx("pressure: %10.4f", (double)report.pressure);
warnx("altitude: %11.4f", (double)report.altitude);
warnx("temperature: %8.4f", (double)report.temperature);
warnx("time: %lld", report.timestamp);
}
errx(0, "PASS");
}
/**
* Reset the driver.
*/
void
reset()
{
int fd = open(BARO_DEVICE_PATH, O_RDONLY);
if (fd < 0)
err(1, "failed ");
if (ioctl(fd, SENSORIOCRESET, 0) < 0)
err(1, "driver reset failed");
if (ioctl(fd, SENSORIOCSPOLLRATE, SENSOR_POLLRATE_DEFAULT) < 0)
err(1, "driver poll restart failed");
exit(0);
}
/**
* Print a little info about the driver.
*/
void
info()
{
if (g_dev == nullptr)
errx(1, "driver not running");
printf("state @ %p\n", g_dev);
g_dev->print_info();
exit(0);
}
/**
* Calculate actual MSL pressure given current altitude
*/
void
calibrate(unsigned altitude)
{
struct baro_report report;
float pressure;
float p1;
int fd = open(BARO_DEVICE_PATH, O_RDONLY);
if (fd < 0)
err(1, "%s open failed (try 'ms5611 start' if the driver is not running)", BARO_DEVICE_PATH);
/* start the sensor polling at max */
if (OK != ioctl(fd, SENSORIOCSPOLLRATE, SENSOR_POLLRATE_MAX))
errx(1, "failed to set poll rate");
/* average a few measurements */
pressure = 0.0f;
for (unsigned i = 0; i < 20; i++) {
struct pollfd fds;
int ret;
ssize_t sz;
/* wait for data to be ready */
fds.fd = fd;
fds.events = POLLIN;
ret = poll(&fds, 1, 1000);
if (ret != 1)
errx(1, "timed out waiting for sensor data");
/* now go get it */
sz = read(fd, &report, sizeof(report));
if (sz != sizeof(report))
err(1, "sensor read failed");
pressure += report.pressure;
}
pressure /= 20; /* average */
pressure /= 10; /* scale from millibar to kPa */
/* tropospheric properties (0-11km) for standard atmosphere */
const float T1 = 15.0 + 273.15; /* temperature at base height in Kelvin */
const float a = -6.5 / 1000; /* temperature gradient in degrees per metre */
const float g = 9.80665f; /* gravity constant in m/s/s */
const float R = 287.05f; /* ideal gas constant in J/kg/K */
warnx("averaged pressure %10.4fkPa at %um", (double)pressure, altitude);
p1 = pressure * (powf(((T1 + (a * (float)altitude)) / T1), (g / (a * R))));
warnx("calculated MSL pressure %10.4fkPa", (double)p1);
/* save as integer Pa */
p1 *= 1000.0f;
if (ioctl(fd, BAROIOCSMSLPRESSURE, (unsigned long)p1) != OK)
err(1, "BAROIOCSMSLPRESSURE");
exit(0);
}
} // namespace
int
ms5611_main(int argc, char *argv[])
{
/*
* Start/load the driver.
*/
if (!strcmp(argv[1], "start"))
ms5611::start();
/*
* Test the driver/device.
*/
if (!strcmp(argv[1], "test"))
ms5611::test();
/*
* Reset the driver.
*/
if (!strcmp(argv[1], "reset"))
ms5611::reset();
/*
* Print driver information.
*/
if (!strcmp(argv[1], "info"))
ms5611::info();
/*
* Perform MSL pressure calibration given an altitude in metres
*/
if (!strcmp(argv[1], "calibrate")) {
if (argc < 2)
errx(1, "missing altitude");
long altitude = strtol(argv[2], nullptr, 10);
ms5611::calibrate(altitude);
}
errx(1, "unrecognised command, try 'start', 'test', 'reset' or 'info'");
}