johannes b583c5f69a ekf-tools: fix late start early end buffer, split imu checks
analyse_logdata_ekf:
- fix the buffer to start the analyses 5s after takeoff and end
them 5s before landing for logs that start or finish in air
- add flag for turning on-off 5s late start early end buffer
- split the combined imu sensor check into checks for vibration,
bias and output predictor