Paul Riseborough 3a029e58c7 logger: Add mode for thermal calibration logging
Logs the IMU and baro data at 10Hz
2017-01-21 11:48:02 +01:00

81 lines
2.8 KiB
C

/****************************************************************************
*
* Copyright (c) 2012-2016 PX4 Development Team. All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions
* are met:
*
* 1. Redistributions of source code must retain the above copyright
* notice, this list of conditions and the following disclaimer.
* 2. Redistributions in binary form must reproduce the above copyright
* notice, this list of conditions and the following disclaimer in
* the documentation and/or other materials provided with the
* distribution.
* 3. Neither the name PX4 nor the names of its contributors may be
* used to endorse or promote products derived from this software
* without specific prior written permission.
*
* THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
* "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
* LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
* FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
* COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
* INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
* BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS
* OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED
* AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
* ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
* POSSIBILITY OF SUCH DAMAGE.
*
****************************************************************************/
/**
* UTC offset (unit: min)
*
* the difference in hours and minutes from Coordinated
* Universal Time (UTC) for a your place and date.
*
* for example, In case of South Korea(UTC+09:00),
* UTC offset is 540 min (9*60)
*
* refer to https://en.wikipedia.org/wiki/List_of_UTC_time_offsets
*
* @unit min
* @min -1000
* @max 1000
* @group SD Logging
*/
PARAM_DEFINE_INT32(SDLOG_UTC_OFFSET, 0);
/**
* Logging Mode
*
* Determines when to start and stop logging. By default, logging is started
* when arming the system, and stopped when disarming.
*
* This parameter is only for the new logger (SYS_LOGGER=1).
*
* @value 0 when armed until disarm (default)
* @value 1 from boot until disarm
* @value 2 from boot until shutdown
* @value 3 from boot until shutdown - IMU and Baro data only (used for thermal calibration)
*
* @min 0
* @max 3
* @reboot_required true
* @group SD Logging
*/
PARAM_DEFINE_INT32(SDLOG_MODE, 0);
/**