Adjust lower bound for CAL_AIR_TUBED_MM to 1.5 mm
Below 1.5 mm the tube pressure drow compensation will result in unrealistic compensation factors causing the measured airspeed to be too high. In addition sensirion recommends a diameter of 1.8 mm or larger for the tubes.
This commit is contained in:
committed by
Lorenz Meier
parent
e39e3b3418
commit
d4ee5a52c9
@@ -68,7 +68,7 @@ PARAM_DEFINE_FLOAT(CAL_AIR_TUBELEN, 0.2f);
|
|||||||
/**
|
/**
|
||||||
* Airspeed sensor tube diameter. Only used for the Tube Pressure Drop Compensation.
|
* Airspeed sensor tube diameter. Only used for the Tube Pressure Drop Compensation.
|
||||||
*
|
*
|
||||||
* @min 0.1
|
* @min 1.5
|
||||||
* @max 100
|
* @max 100
|
||||||
* @unit mm
|
* @unit mm
|
||||||
*
|
*
|
||||||
|
|||||||
Reference in New Issue