mirror of
https://gitee.com/mirrors_PX4/PX4-Autopilot.git
synced 2026-10-16 21:33:33 +08:00
ekf2: mag fusion don't update all states or tilt by default
- cleanup some of the legacy mag flags
This commit is contained in:
committed by
Mathieu Bresciani
parent
bfc39cf341
commit
5173830718
@@ -101,6 +101,11 @@ void Ekf::controlMagFusion()
|
||||
_control_status.flags.synthetic_mag_z = false;
|
||||
}
|
||||
|
||||
// reset flags
|
||||
_fault_status.flags.bad_mag_x = false;
|
||||
_fault_status.flags.bad_mag_y = false;
|
||||
_fault_status.flags.bad_mag_z = false;
|
||||
|
||||
|
||||
resetEstimatorAidStatus(aid_src);
|
||||
aid_src.timestamp_sample = mag_sample.time_us;
|
||||
@@ -131,6 +136,10 @@ void Ekf::controlMagFusion()
|
||||
const float innov_gate = math::max(_params.mag_innov_gate, 1.f);
|
||||
setEstimatorAidStatusTestRatio(aid_src, innov_gate);
|
||||
|
||||
// Perform an innovation consistency check and report the result
|
||||
_innov_check_fail_status.flags.reject_mag_x = (aid_src.test_ratio[0] > 1.f);
|
||||
_innov_check_fail_status.flags.reject_mag_y = (aid_src.test_ratio[1] > 1.f);
|
||||
_innov_check_fail_status.flags.reject_mag_z = (aid_src.test_ratio[2] > 1.f);
|
||||
|
||||
// determine if we should use mag fusion
|
||||
bool continuing_conditions_passing = (_params.mag_fusion_type != MagFuseType::NONE)
|
||||
@@ -208,7 +217,7 @@ void Ekf::controlMagFusion()
|
||||
// states for the first few observations.
|
||||
fuseDeclination(0.02f);
|
||||
_mag_decl_cov_reset = true;
|
||||
fuseMag(mag_sample.mag, H, aid_src, false);
|
||||
fuseMag(mag_sample.mag, R_MAG, H, aid_src);
|
||||
|
||||
} else {
|
||||
// The normal sequence is to fuse the magnetometer data first before fusing
|
||||
@@ -216,7 +225,14 @@ void Ekf::controlMagFusion()
|
||||
// declination angle over time.
|
||||
const bool update_all_states = _control_status.flags.mag_3D || _control_status.flags.mag_hdg;
|
||||
const bool update_tilt = _control_status.flags.mag_3D;
|
||||
fuseMag(mag_sample.mag, H, aid_src, update_all_states, update_tilt);
|
||||
fuseMag(mag_sample.mag, R_MAG, H, aid_src, update_all_states, update_tilt);
|
||||
|
||||
// the innovation variance contribution from the state covariances is negative which means the covariance matrix is badly conditioned
|
||||
if (update_all_states && update_tilt) {
|
||||
_fault_status.flags.bad_mag_x = (aid_src.innovation_variance[0] < aid_src.observation_variance[0]);
|
||||
_fault_status.flags.bad_mag_y = (aid_src.innovation_variance[1] < aid_src.observation_variance[1]);
|
||||
_fault_status.flags.bad_mag_z = (aid_src.innovation_variance[2] < aid_src.observation_variance[2]);
|
||||
}
|
||||
|
||||
if (_control_status.flags.mag_dec) {
|
||||
fuseDeclination(0.5f);
|
||||
@@ -276,19 +292,19 @@ void Ekf::controlMagFusion()
|
||||
bool reset_heading = !_control_status.flags.yaw_align;
|
||||
|
||||
resetMagStates(_mag_lpf.getState(), reset_heading);
|
||||
aid_src.time_last_fuse = _time_delayed_us;
|
||||
_nb_mag_3d_reset_available = 2;
|
||||
|
||||
if (reset_heading) {
|
||||
_control_status.flags.yaw_align = true;
|
||||
}
|
||||
|
||||
} else {
|
||||
ECL_INFO("starting %s fusion", AID_SRC_NAME);
|
||||
fuseMag(mag_sample.mag, H, aid_src, false);
|
||||
if (fuseMag(mag_sample.mag, R_MAG, H, aid_src)) {
|
||||
ECL_INFO("starting %s fusion", AID_SRC_NAME);
|
||||
_nb_mag_3d_reset_available = 2;
|
||||
}
|
||||
}
|
||||
|
||||
aid_src.time_last_fuse = _time_delayed_us;
|
||||
|
||||
_nb_mag_3d_reset_available = 2;
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
@@ -50,41 +50,22 @@
|
||||
|
||||
#include <mathlib/mathlib.h>
|
||||
|
||||
bool Ekf::fuseMag(const Vector3f &mag, VectorState &H, estimator_aid_source3d_s &aid_src, bool update_all_states, bool update_tilt)
|
||||
bool Ekf::fuseMag(const Vector3f &mag, const float R_MAG, VectorState &H, estimator_aid_source3d_s &aid_src, bool update_all_states, bool update_tilt)
|
||||
{
|
||||
// XYZ Measurement uncertainty. Need to consider timing errors for fast rotations
|
||||
const float R_MAG = math::max(sq(_params.mag_noise), sq(0.01f));
|
||||
|
||||
const auto state_vector = _state.vector();
|
||||
|
||||
if (update_all_states) {
|
||||
_fault_status.flags.bad_mag_x = (aid_src.innovation_variance[0] < aid_src.observation_variance[0]);
|
||||
_fault_status.flags.bad_mag_y = (aid_src.innovation_variance[1] < aid_src.observation_variance[1]);
|
||||
_fault_status.flags.bad_mag_z = (aid_src.innovation_variance[2] < aid_src.observation_variance[2]);
|
||||
|
||||
} else {
|
||||
_fault_status.flags.bad_mag_x = false;
|
||||
_fault_status.flags.bad_mag_y = false;
|
||||
_fault_status.flags.bad_mag_z = false;
|
||||
}
|
||||
|
||||
// Perform an innovation consistency check and report the result
|
||||
_innov_check_fail_status.flags.reject_mag_x = (aid_src.test_ratio[0] > 1.f);
|
||||
_innov_check_fail_status.flags.reject_mag_y = (aid_src.test_ratio[1] > 1.f);
|
||||
_innov_check_fail_status.flags.reject_mag_z = (aid_src.test_ratio[2] > 1.f);
|
||||
|
||||
// if any axis fails, abort the mag fusion
|
||||
// if any axis failed, abort the mag fusion
|
||||
if (aid_src.innovation_rejected) {
|
||||
return false;
|
||||
}
|
||||
|
||||
const auto state_vector = _state.vector();
|
||||
|
||||
bool fused[3] {false, false, false};
|
||||
|
||||
// update the states and covariance using sequential fusion of the magnetometer components
|
||||
for (uint8_t index = 0; index <= 2; index++) {
|
||||
// Calculate Kalman gains and observation jacobians
|
||||
if (index == 0) {
|
||||
// everything was already computed above
|
||||
// everything was already computed
|
||||
|
||||
} else if (index == 1) {
|
||||
// recalculate innovation variance because state covariances have changed due to previous fusion (linearise using the same initial state for all axes)
|
||||
@@ -108,13 +89,6 @@ bool Ekf::fuseMag(const Vector3f &mag, VectorState &H, estimator_aid_source3d_s
|
||||
}
|
||||
|
||||
if (aid_src.innovation_variance[index] < R_MAG) {
|
||||
// the innovation variance contribution from the state covariances is negative which means the covariance matrix is badly conditioned
|
||||
if (update_all_states) {
|
||||
_fault_status.flags.bad_mag_x = (aid_src.innovation_variance[0] < aid_src.observation_variance[0]);
|
||||
_fault_status.flags.bad_mag_y = (aid_src.innovation_variance[1] < aid_src.observation_variance[1]);
|
||||
_fault_status.flags.bad_mag_z = (aid_src.innovation_variance[2] < aid_src.observation_variance[2]);
|
||||
}
|
||||
|
||||
ECL_ERR("mag numerical error covariance reset");
|
||||
|
||||
// we need to re-initialise covariances and abort this fusion step
|
||||
|
||||
@@ -758,7 +758,7 @@ private:
|
||||
|
||||
#if defined(CONFIG_EKF2_MAGNETOMETER)
|
||||
// ekf sequential fusion of magnetometer measurements
|
||||
bool fuseMag(const Vector3f &mag, VectorState &H, estimator_aid_source3d_s &aid_src, bool update_all_states = true, bool update_tilt = true);
|
||||
bool fuseMag(const Vector3f &mag, const float R_MAG, VectorState &H, estimator_aid_source3d_s &aid_src, bool update_all_states = false, bool update_tilt = false);
|
||||
|
||||
// fuse magnetometer declination measurement
|
||||
// argument passed in is the declination uncertainty in radians
|
||||
|
||||
Reference in New Issue