sensor calibration delete temperature (CAL_ACCx_TEMP, CAL_GYROx_TEMP, CAL_MAGx_TEMP)

- this was an experiment to casually monitor sensor offsets relative to temperature, but now that all calibration offsets can be adjusted post-flight the stored temperature can be misleading
 - deleting to save a little bit of flash (and storing the temperature wasn't useful)
This commit is contained in:
Daniel Agar
2022-03-12 11:38:49 -05:00
committed by GitHub
parent aa64789792
commit 3d54d25867
15 changed files with 11 additions and 196 deletions
@@ -246,7 +246,6 @@ void GyroCalibration::Run()
const Vector3f old_offset{_gyro_calibration[gyro].offset()};
if (_gyro_calibration[gyro].set_offset(_gyro_mean[gyro].mean())) {
_gyro_calibration[gyro].set_temperature(_temperature[gyro]);
calibration_updated = true;