Set full voltage correctly to ensure percentage range fits. Force all users to new value by param renaming. Since this will tend to show batteries as more drained than before, this is a change in a safe direction and will not trigger unnoticed discharges.

This commit is contained in:
Lorenz Meier
2014-07-20 16:23:43 +02:00
parent e21cb64553
commit 3935540c7d
2 changed files with 4 additions and 4 deletions
+1 -1
View File
@@ -65,7 +65,7 @@ PARAM_DEFINE_FLOAT(BAT_V_EMPTY, 3.4f);
*
* @group Battery Calibration
*/
PARAM_DEFINE_FLOAT(BAT_V_FULL, 4.15f);
PARAM_DEFINE_FLOAT(BAT_V_CHARGED, 4.2f);
/**
* Number of cells.