mirror of
https://gitee.com/mirrors_PX4/PX4-Autopilot.git
synced 2026-10-31 11:41:36 +08:00
refactor(simulation/battery_simulator): convert params.c to module.yaml
Convert 1 parameter file(s) from legacy C format to YAML module configuration.
This commit is contained in:
@@ -38,6 +38,8 @@ px4_add_module(
|
|||||||
SRCS
|
SRCS
|
||||||
BatterySimulator.cpp
|
BatterySimulator.cpp
|
||||||
BatterySimulator.hpp
|
BatterySimulator.hpp
|
||||||
|
MODULE_CONFIG
|
||||||
|
battery_simulator_params.yaml
|
||||||
DEPENDS
|
DEPENDS
|
||||||
battery
|
battery
|
||||||
mathlib
|
mathlib
|
||||||
|
|||||||
@@ -1,71 +0,0 @@
|
|||||||
/****************************************************************************
|
|
||||||
*
|
|
||||||
* Copyright (c) 2020 PX4 Development Team. All rights reserved.
|
|
||||||
*
|
|
||||||
* Redistribution and use in source and binary forms, with or without
|
|
||||||
* modification, are permitted provided that the following conditions
|
|
||||||
* are met:
|
|
||||||
*
|
|
||||||
* 1. Redistributions of source code must retain the above copyright
|
|
||||||
* notice, this list of conditions and the following disclaimer.
|
|
||||||
* 2. Redistributions in binary form must reproduce the above copyright
|
|
||||||
* notice, this list of conditions and the following disclaimer in
|
|
||||||
* the documentation and/or other materials provided with the
|
|
||||||
* distribution.
|
|
||||||
* 3. Neither the name PX4 nor the names of its contributors may be
|
|
||||||
* used to endorse or promote products derived from this software
|
|
||||||
* without specific prior written permission.
|
|
||||||
*
|
|
||||||
* THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
|
|
||||||
* "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
|
|
||||||
* LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
|
|
||||||
* FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
|
|
||||||
* COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
|
|
||||||
* INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
|
|
||||||
* BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS
|
|
||||||
* OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED
|
|
||||||
* AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
|
|
||||||
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
|
|
||||||
* ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
|
|
||||||
* POSSIBILITY OF SUCH DAMAGE.
|
|
||||||
*
|
|
||||||
****************************************************************************/
|
|
||||||
|
|
||||||
/**
|
|
||||||
* Simulator Battery enabled
|
|
||||||
*
|
|
||||||
* Enable or disable the internal battery simulation. This is useful
|
|
||||||
* when the battery is simulated externally and interfaced with PX4
|
|
||||||
* through MAVLink for example.
|
|
||||||
*
|
|
||||||
* @boolean
|
|
||||||
* @group SITL
|
|
||||||
*/
|
|
||||||
PARAM_DEFINE_INT32(SIM_BAT_ENABLE, 1);
|
|
||||||
|
|
||||||
/**
|
|
||||||
* Simulator Battery drain interval
|
|
||||||
*
|
|
||||||
* @min 1
|
|
||||||
* @max 86400
|
|
||||||
* @increment 1
|
|
||||||
* @unit s
|
|
||||||
*
|
|
||||||
* @group SITL
|
|
||||||
*/
|
|
||||||
PARAM_DEFINE_FLOAT(SIM_BAT_DRAIN, 60);
|
|
||||||
|
|
||||||
/**
|
|
||||||
* Simulator Battery minimal percentage.
|
|
||||||
*
|
|
||||||
* Can be used to alter the battery level during SITL- or HITL-simulation on the fly.
|
|
||||||
* Particularly useful for testing different low-battery behaviour.
|
|
||||||
*
|
|
||||||
* @min 0
|
|
||||||
* @max 100
|
|
||||||
* @increment 0.1
|
|
||||||
* @unit %
|
|
||||||
*
|
|
||||||
* @group SITL
|
|
||||||
*/
|
|
||||||
PARAM_DEFINE_FLOAT(SIM_BAT_MIN_PCT, 50.0f);
|
|
||||||
@@ -0,0 +1,34 @@
|
|||||||
|
module_name: battery_simulator
|
||||||
|
parameters:
|
||||||
|
- group: SITL
|
||||||
|
definitions:
|
||||||
|
SIM_BAT_ENABLE:
|
||||||
|
description:
|
||||||
|
short: Simulator Battery enabled
|
||||||
|
long: |-
|
||||||
|
Enable or disable the internal battery simulation. This is useful
|
||||||
|
when the battery is simulated externally and interfaced with PX4
|
||||||
|
through MAVLink for example.
|
||||||
|
type: boolean
|
||||||
|
default: 1
|
||||||
|
SIM_BAT_DRAIN:
|
||||||
|
description:
|
||||||
|
short: Simulator Battery drain interval
|
||||||
|
type: float
|
||||||
|
default: 60
|
||||||
|
min: 1
|
||||||
|
max: 86400
|
||||||
|
increment: 1
|
||||||
|
unit: s
|
||||||
|
SIM_BAT_MIN_PCT:
|
||||||
|
description:
|
||||||
|
short: Simulator Battery minimal percentage
|
||||||
|
long: |-
|
||||||
|
Can be used to alter the battery level during SITL- or HITL-simulation on the fly.
|
||||||
|
Particularly useful for testing different low-battery behaviour.
|
||||||
|
type: float
|
||||||
|
default: 50.0
|
||||||
|
min: 0
|
||||||
|
max: 100
|
||||||
|
increment: 0.1
|
||||||
|
unit: '%'
|
||||||
Reference in New Issue
Block a user